Pre-routed boards (1200 × 600 × 21 mm, 12–15 kg) laid directly onto solid insulated ground floors or upper floors. Designed for new builds and renovations.
We design the board layout to match each room's required temperature, so your installer simply copies the pattern.
Heat-pump friendly: flow temps 28–35°C
48 N/mm² compressive strength (concrete-grade)
1501 kJ/m³·K heat storage — fast warm-up
Δt of only 1–2°C for max efficiency
Min 25–32% energy saving vs other wet UFH
Suitable for residential and commercial
Dry cover board system — fits straight over the pipes. Floor is walkable immediately, no commissioning delay.
Special compound cover — a 2–4 mm pour that covers board and pipes in one pass. Typically cures in 2–3 days.
Works with tiles, LVT, laminate and engineered wood
Heat output charts supplied for both options
Layouts engineered around your final floor finish
Supply only — your installer fits the cover
All figures in W/m². Use these to size the system to each room.
| Flow | Tiles | LVT | Laminate | Eng. Wood |
|---|---|---|---|---|
| 25°C | 34.2 | 31.32 | 29.52 | 27.72 |
| 28°C | 57.95 | 53.07 | 50.02 | 46.97 |
| 32°C | 90.25 | 82.65 | 77.9 | 73.15 |
| 35°C | 113 | 103 | 97.58 | 91.63 |
| Flow | Tiles | LVT | Laminate | Eng. Wood |
|---|---|---|---|---|
| 25°C | 40.8 | 37.41 | 35.26 | 33.11 |
| 28°C | 69.35 | 63.51 | 59.86 | 56 |
| 32°C | 105 | 96.57 | 91.02 | 85.47 |
| 35°C | 133 | 121 | 114 | 107 |
© 2026 Superwarm Floors. Supply only.